PURPOSE: To compare corneal biomechanics between patients with ocular graft versus-host disease (oGVHD) and healthy subjects (controls), and to further correlate these values with ocular and hematological characteristics. MATERIALS AND METHODS: The following procedures were performed in oGVHD patients and controls: Schirmer test (ST), break-up time (BUT), corneal and conjunctival staining, tear matrix metalloproteinase-9 (MMP-9) assay (InflammaDry test, Rapid Pathogen Screening, Inc, Sarasota, FL). Corneal biomechanics were calculated by using ocular response analyzer (ORA, Reichert Instruments, Depew, New York, USA). The Mann-Whitney U test was used to compare continuous variables between oGVHD patients and controls. Correlations of corneal biomechanics with ocular and hematological parameters were examined using Spearman's correlation. RESULTS: A total of 45 oGVHD patients (mean age ± SD, 51.5 ± 7.1 years) and 34 controls (47.8 ± 6.1 years) were included. Patients with oGVHD showed significantly lower values of corneal hysteresis (CH) and corneal resistance factor (CRF) compared to controls (respectively, 9.4 ± 1.8 mmHg vs 11.6 ± 1.6 and 9.7 ± 1.4 mmHg vs 12.3 ± 1.3; always p<0.001). Twenty-nine of the oGVHD eyes (64.4%) were strong-positive for MMP-9, while 16 (35.6%) were weak-positive. Conversely, only 4 of the control eyes (11.8%) were weak-positive for MMP-9. In patients with oGVHD, CH was significantly correlated with corneal staining (Rs = -0.316, p = 0.035), conjunctival staining (Rs = -0.437, p = 0.003), ST (Rs = 0.390, p = 0.008), BUT (Rs = 0.423, p = 0.004), oGVHD severity grade (Rs = -0.383, p = 0.009), and MMP-9 positivity grade (Rs = -0.429, p = 0.003), while CRF was correlated only with corneal staining (Rs = -0.317, p = 0.034). CONCLUSIONS: Corneal biomechanics are reduced in patients with oGVHD, and CH is negatively correlated with disease severity grade and MMP-9 tear levels.

Corneal biomechanical alterations in patients with chronic ocular Graft Versus-Host Disease

Giannaccare G;Scorcia V;
2019-01-01

Abstract

PURPOSE: To compare corneal biomechanics between patients with ocular graft versus-host disease (oGVHD) and healthy subjects (controls), and to further correlate these values with ocular and hematological characteristics. MATERIALS AND METHODS: The following procedures were performed in oGVHD patients and controls: Schirmer test (ST), break-up time (BUT), corneal and conjunctival staining, tear matrix metalloproteinase-9 (MMP-9) assay (InflammaDry test, Rapid Pathogen Screening, Inc, Sarasota, FL). Corneal biomechanics were calculated by using ocular response analyzer (ORA, Reichert Instruments, Depew, New York, USA). The Mann-Whitney U test was used to compare continuous variables between oGVHD patients and controls. Correlations of corneal biomechanics with ocular and hematological parameters were examined using Spearman's correlation. RESULTS: A total of 45 oGVHD patients (mean age ± SD, 51.5 ± 7.1 years) and 34 controls (47.8 ± 6.1 years) were included. Patients with oGVHD showed significantly lower values of corneal hysteresis (CH) and corneal resistance factor (CRF) compared to controls (respectively, 9.4 ± 1.8 mmHg vs 11.6 ± 1.6 and 9.7 ± 1.4 mmHg vs 12.3 ± 1.3; always p<0.001). Twenty-nine of the oGVHD eyes (64.4%) were strong-positive for MMP-9, while 16 (35.6%) were weak-positive. Conversely, only 4 of the control eyes (11.8%) were weak-positive for MMP-9. In patients with oGVHD, CH was significantly correlated with corneal staining (Rs = -0.316, p = 0.035), conjunctival staining (Rs = -0.437, p = 0.003), ST (Rs = 0.390, p = 0.008), BUT (Rs = 0.423, p = 0.004), oGVHD severity grade (Rs = -0.383, p = 0.009), and MMP-9 positivity grade (Rs = -0.429, p = 0.003), while CRF was correlated only with corneal staining (Rs = -0.317, p = 0.034). CONCLUSIONS: Corneal biomechanics are reduced in patients with oGVHD, and CH is negatively correlated with disease severity grade and MMP-9 tear levels.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/10090
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact