Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS
Backgrounds: Minimally Invasive Liver Surgery (MILS), encompassing laparoscopic (L-MILS) and robotic (R-MILS) approaches, has revolutionized liver surgery, offering reduced morbidity, shorter hospital stays, and improved outcomes while maintaining oncological efficacy. Despite the widespread use of L-MILS, parenchyma liver transection techniques and devices remain debated. This study investigates the adoption of transection devices (TDs) in MILS among 86 hospitals, focusing on surgical practices, device utilization, and outcomes. Methods: The Italian Society of Endoscopic Surgery (SICE) endorsed a cross-sectional internet-based survey targeting general and Hepato-Pancreato-Biliary surgeons. Results: Responses from 86 centers revealed that 77% of institutions is available a robotic platform, with an adoption rate of 87.50% in high-volume centers. L-MILS remains the predominant technique for liver resections, also in case of major hepatectomies, although R-MILS is increasingly utilized. For minor L-MILS, more than 50% of respondents use ultrasonic shears and electrosurgical pencil and advanced bipolar devices, while about 40% of surgeons adopt Cavitronic Ultrasonic Surgical Aspirator (CUSA) in major resections. R-MILS procedures predominantly used Maryland bipolar forceps and vessel sealers, with hybrid techniques (30%) integrating laparoscopic devices (e.g., CUSA) to address robotic device limitations. Conclusion: The minimally invasive approach to liver parenchymal transection is a key component of this surgical procedure. For major hepatectomies, the CUSA device remains the most effective tool, whereas ultrasonic shears, electrosurgical pencil, and advanced bipolar devices are more suited for minor resections. Despite limited access to specialized instruments, R-MILS achieves favorable outcomes in liver transection by employing the crash-clamp technique or hybrid strategies.
Devices for minimally invasive liver parenchyma transection: the SICE (Italian Society of Endoscopic Surgery) Italian and International survey
Backgrounds: Minimally Invasive Liver Surgery (MILS), encompassing laparoscopic (L-MILS) and robotic (R-MILS) approaches, has revolutionized liver surgery, offering reduced morbidity, shorter hospital stays, and improved outcomes while maintaining oncological efficacy. Despite the widespread use of L-MILS, parenchyma liver transection techniques and devices remain debated. This study investigates the adoption of transection devices (TDs) in MILS among 86 hospitals, focusing on surgical practices, device utilization, and outcomes. Methods: The Italian Society of Endoscopic Surgery (SICE) endorsed a cross-sectional internet-based survey targeting general and Hepato-Pancreato-Biliary surgeons. Results: Responses from 86 centers revealed that 77% of institutions is available a robotic platform, with an adoption rate of 87.50% in high-volume centers. L-MILS remains the predominant technique for liver resections, also in case of major hepatectomies, although R-MILS is increasingly utilized. For minor L-MILS, more than 50% of respondents use ultrasonic shears and electrosurgical pencil and advanced bipolar devices, while about 40% of surgeons adopt Cavitronic Ultrasonic Surgical Aspirator (CUSA) in major resections. R-MILS procedures predominantly used Maryland bipolar forceps and vessel sealers, with hybrid techniques (30%) integrating laparoscopic devices (e.g., CUSA) to address robotic device limitations. Conclusion: The minimally invasive approach to liver parenchymal transection is a key component of this surgical procedure. For major hepatectomies, the CUSA device remains the most effective tool, whereas ultrasonic shears, electrosurgical pencil, and advanced bipolar devices are more suited for minor resections. Despite limited access to specialized instruments, R-MILS achieves favorable outcomes in liver transection by employing the crash-clamp technique or hybrid strategies.
High energy device High volume Indocyanine green fluorescence Laparoscopic liver surgery Liver parenchyma Liver surgery Low volume Medium volume Minimally invasive surgery Robotic liver surgery
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/112182
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
0
0
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.