Purpose Identification of proteolytic peptides from matrix-assisted laser desorption/ionization (MALDI) imaging remains a challenge. The low fragmentation yields obtained using in situ post source decay impairs identification. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is an alternative to in situ MS/MS, but leads to multiple identification candidates for a given mass. The authors propose to use LC-MS/MS-based biomarker discovery results to reliably identify proteolytic peptides from MALDI imaging. Experimental design The authors defined m/z values of interest for high grade squamous intraepithelial lesion (HSIL) by MALDI imaging. In parallel the authors used data from a biomarker discovery study to correlate m/z from MALDI imaging with masses of peptides identified by LC-MS/MS in HSIL. The authors neglected candidates that were not significantly more abundant in HSIL according to the biomarker discovery investigation. Results The authors assigned identifications to three m/z of interest. The number of possible identifiers for MALDI imaging m/z peaks using LC-MS/MS-based biomarker discovery studies was reduced by about tenfold compared using a single LC-MS/MS experiment. One peptide identification candidate was validated by immunohistochemistry. Conclusion and clinical relevance: This concept combines LC-MS/MS-based quantitative proteomics with MALDI imaging and allows reliable peptide identification. Public datasets from LC-MS/MS biomarker discovery experiments will be useful to identify MALDI imaging m/z peaks.

Identification of MALDI Imaging Proteolytic Peptides Using LC-MS/MS-Based Biomarker Discovery Data: A Proof of Concept

Casadonte R;
2019-01-01

Abstract

Purpose Identification of proteolytic peptides from matrix-assisted laser desorption/ionization (MALDI) imaging remains a challenge. The low fragmentation yields obtained using in situ post source decay impairs identification. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is an alternative to in situ MS/MS, but leads to multiple identification candidates for a given mass. The authors propose to use LC-MS/MS-based biomarker discovery results to reliably identify proteolytic peptides from MALDI imaging. Experimental design The authors defined m/z values of interest for high grade squamous intraepithelial lesion (HSIL) by MALDI imaging. In parallel the authors used data from a biomarker discovery study to correlate m/z from MALDI imaging with masses of peptides identified by LC-MS/MS in HSIL. The authors neglected candidates that were not significantly more abundant in HSIL according to the biomarker discovery investigation. Results The authors assigned identifications to three m/z of interest. The number of possible identifiers for MALDI imaging m/z peaks using LC-MS/MS-based biomarker discovery studies was reduced by about tenfold compared using a single LC-MS/MS experiment. One peptide identification candidate was validated by immunohistochemistry. Conclusion and clinical relevance: This concept combines LC-MS/MS-based quantitative proteomics with MALDI imaging and allows reliable peptide identification. Public datasets from LC-MS/MS biomarker discovery experiments will be useful to identify MALDI imaging m/z peaks.
2019
Identification, liquid chromatography, tandem mass spectrometry, matrix-assisted laser desorption/ionization imaging, microproteomics
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/120732
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 18
social impact