Study Objective: compare the safety and the effectiveness of two tissue morcellators, i.e. Gynecare Morcellex(r) and Rotocut G1(r), during laparoscopic supracervical hysterectomy and myomectomy. Design: randomized controlled trial. Design classification: Evidence I. Setting: Academic Department of Obstetrics and Gynecology, University Magna Graecia of Catanzaro. Patients: seventy-four patients with symptomatic fibroid uterine scheduled to laparoscopic supracervical hysterectomy or myomectomy. Interventions: laparoscopic supracervical hysterectomy and myomectomy followed by tissue morcellating with use of Gynecare Morcellex(r) (experimental group) or Rotocut G1(r) (control group). Results: any difference was not detected between groups, while a significant (P<0.05) difference in handling score was detected in the experimental group in comparison with control group. Conclusion: Gynecare Morcellex(r) is a safe and effective instrument that should be potentially preferred by surgeons with a suboptimal grade of expertise in laparoscopic tissue morcellation. © Copyright 2009, CIC Edizioni Internazionali.

A randomized controlled study comparing two tissue morcellators: Gynecare Morcellex® versus Rotocut G1

Palomba S;Venturella R;Zullo F  
2009-01-01

Abstract

Study Objective: compare the safety and the effectiveness of two tissue morcellators, i.e. Gynecare Morcellex(r) and Rotocut G1(r), during laparoscopic supracervical hysterectomy and myomectomy. Design: randomized controlled trial. Design classification: Evidence I. Setting: Academic Department of Obstetrics and Gynecology, University Magna Graecia of Catanzaro. Patients: seventy-four patients with symptomatic fibroid uterine scheduled to laparoscopic supracervical hysterectomy or myomectomy. Interventions: laparoscopic supracervical hysterectomy and myomectomy followed by tissue morcellating with use of Gynecare Morcellex(r) (experimental group) or Rotocut G1(r) (control group). Results: any difference was not detected between groups, while a significant (P<0.05) difference in handling score was detected in the experimental group in comparison with control group. Conclusion: Gynecare Morcellex(r) is a safe and effective instrument that should be potentially preferred by surgeons with a suboptimal grade of expertise in laparoscopic tissue morcellation. © Copyright 2009, CIC Edizioni Internazionali.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/16431
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact