Cerebral blood flow and cerebral blood volume were measured and quantified using single photon emission computed tomography before and after unilateral endarterectomy in 3 patients with bilateral severe lesions of the internal carotid artery. These parameters were measured using an intravenous injection of 133 Xenon and 99m Technetium respectively. Before endarterectomy cerebral blood volume was high in all patients suggesting a focal vasodilatation in response to a reduced cerebral perfusion pressure. After endarterectomy a decrease of cerebral blood volume and an increase of cerebral blood flow were observed. These preliminary results confirm that the hemodynamic adaptative mechanisms secondary to carotid occlusion are reversible when the stenosis is removed and demonstrate that these changes can be accurately measured using single photon emission computed tomography. Positron emission tomography was previously considered to be the only method able to quantify cerebral blood volume in man. Single photon emission computed tomography can also be considered a reliable technique to measure both cerebral blood flow and cerebral blood volume. This technique can then be used to assess individual cerebral vascular adaptative states and to evaluate the influence of cerebral hemodynamic changes on stroke occurrence in large longitudinal studies.

Cerebral blood volume, endarterectomy and SPECT

Sabatini U;
1991-01-01

Abstract

Cerebral blood flow and cerebral blood volume were measured and quantified using single photon emission computed tomography before and after unilateral endarterectomy in 3 patients with bilateral severe lesions of the internal carotid artery. These parameters were measured using an intravenous injection of 133 Xenon and 99m Technetium respectively. Before endarterectomy cerebral blood volume was high in all patients suggesting a focal vasodilatation in response to a reduced cerebral perfusion pressure. After endarterectomy a decrease of cerebral blood volume and an increase of cerebral blood flow were observed. These preliminary results confirm that the hemodynamic adaptative mechanisms secondary to carotid occlusion are reversible when the stenosis is removed and demonstrate that these changes can be accurately measured using single photon emission computed tomography. Positron emission tomography was previously considered to be the only method able to quantify cerebral blood volume in man. Single photon emission computed tomography can also be considered a reliable technique to measure both cerebral blood flow and cerebral blood volume. This technique can then be used to assess individual cerebral vascular adaptative states and to evaluate the influence of cerebral hemodynamic changes on stroke occurrence in large longitudinal studies.
1991
cerebral blood flow; cerebral blood volume; carotid endarterectomy
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/3339
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 2
social impact