Objective Stentless aortic valves have been developed to overcome obstructive limitations associated with stented bioprostheses. The aim of the current multi-institutional study was to compare hemodynamics of transcatheter (TAVR) and the Freedom SOLO Stentless (FS) valve in an intermediate risk population undergoing surgical aortic valve replacement. Methods From 2010 to 2014, 420 consecutive patients underwent isolated surgical aortic valve replacement with FS and 375 patients underwent TAVR. Only patients with intermediate operative risk (Society of Thoracic Surgeons score 4-10) and small aortic annulus (≤23 mm) were included. After a propensity matched analysis 142 patients in each group were selected. Thirty-day postoperative clinical and echocardiographic parameters were evaluated. Results Mean prosthesis diameter was 22.2 ± 0.9 mm for FS and 22.4 ± 1.0 mm for TAVR. In-hospital mortality was 2.1% for FS and 6.3% for TAVR (P = .02). Postoperative FS peak gradients were 19.1 ± 9.6 mm Hg (mean 10.8 ± 5.9 mm Hg); TAVR peak gradients were 20.2 ± 9.5 mm Hg (mean 10.7 ± 6.9 mm Hg) P = .57 (P = .88). Postoperative effective orifice area was 1.93 ± 0.52 cm2 for FS and 1.83 ± 0.3 cm2 for TAVR (P = .65). There was no prostheses-patient mismatch in either group. Postoperative grade 2-3 paravalvular leak was present in 3.5% for TAVR and 0.7% for FS. Postoperative permanent pacemaker implant rate was 12% for TAVR and only 1 case (0.7%) in the FS group (P < .001). Conclusions In patients with small aortic annulus and intermediate risk, both FS and TAVR demonstrated similar excellent hemodynamic performance. TAVR demonstrated greater mortality and rates of pacemaker insertion. Further studies are warranted to validate TAVR indications in this subset of patients.

Early hemodynamics and clinical outcomes of isolated aortic valve replacement with stentless or transcatheter valve in intermediate-risk patients

Santarpino G.;
2017-01-01

Abstract

Objective Stentless aortic valves have been developed to overcome obstructive limitations associated with stented bioprostheses. The aim of the current multi-institutional study was to compare hemodynamics of transcatheter (TAVR) and the Freedom SOLO Stentless (FS) valve in an intermediate risk population undergoing surgical aortic valve replacement. Methods From 2010 to 2014, 420 consecutive patients underwent isolated surgical aortic valve replacement with FS and 375 patients underwent TAVR. Only patients with intermediate operative risk (Society of Thoracic Surgeons score 4-10) and small aortic annulus (≤23 mm) were included. After a propensity matched analysis 142 patients in each group were selected. Thirty-day postoperative clinical and echocardiographic parameters were evaluated. Results Mean prosthesis diameter was 22.2 ± 0.9 mm for FS and 22.4 ± 1.0 mm for TAVR. In-hospital mortality was 2.1% for FS and 6.3% for TAVR (P = .02). Postoperative FS peak gradients were 19.1 ± 9.6 mm Hg (mean 10.8 ± 5.9 mm Hg); TAVR peak gradients were 20.2 ± 9.5 mm Hg (mean 10.7 ± 6.9 mm Hg) P = .57 (P = .88). Postoperative effective orifice area was 1.93 ± 0.52 cm2 for FS and 1.83 ± 0.3 cm2 for TAVR (P = .65). There was no prostheses-patient mismatch in either group. Postoperative grade 2-3 paravalvular leak was present in 3.5% for TAVR and 0.7% for FS. Postoperative permanent pacemaker implant rate was 12% for TAVR and only 1 case (0.7%) in the FS group (P < .001). Conclusions In patients with small aortic annulus and intermediate risk, both FS and TAVR demonstrated similar excellent hemodynamic performance. TAVR demonstrated greater mortality and rates of pacemaker insertion. Further studies are warranted to validate TAVR indications in this subset of patients.
2017
haemodynamics; intermediate risk; small aortic annulus; stentless aortic prosthesis; transcatheter aortic valves; Aged; Aortic Valve; Aortic Valve Stenosis; Echocardiography; Europe; Female; Follow-Up Studies; Heart Valve Prosthesis Implantation; Hemodynamics; Hospital Mortality; Humans; Male; Prognosis; Prosthesis Design; Retrospective Studies; Risk Factors; Survival Rate; Time Factors; Transcatheter Aortic Valve Replacement; Heart Valve Prosthesis
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/60418
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 14
social impact