In the last years, an increasing proportion of high-risk patients undergo surgical aortic valve replacement. In order to reduce the risk associated with cross-clamp time or cardioplegic ischemic time, sutureless aortic prostheses have been developed. These bioprosthetic valves are not hand sewn, and this technological advance translates into reduced implantation times, thus improving outcome of patients referred for aortic valve replacement. At present, three sutureless bioprostheses are available on the market: 3f Enable (Medtronic Inc., Minneapolis, Minnesota, USA), Perceval (Sorin Group, Saluggia, Italy) and Intuity (Edwards Lifesciences, Irvine, California, USA). This article provides an overview of the available literature on sutureless aortic valves with the aim to better define current role and future perspectives of sutureless aortic bioprostheses for the treatment of aortic valve stenosis. © 2014 Il Pensiero Scientifico Editore.

Use of sutureless aortic valve prosthesis in cardiac surgery: Current results and future perspective

Santarpino G.
;
2014-01-01

Abstract

In the last years, an increasing proportion of high-risk patients undergo surgical aortic valve replacement. In order to reduce the risk associated with cross-clamp time or cardioplegic ischemic time, sutureless aortic prostheses have been developed. These bioprosthetic valves are not hand sewn, and this technological advance translates into reduced implantation times, thus improving outcome of patients referred for aortic valve replacement. At present, three sutureless bioprostheses are available on the market: 3f Enable (Medtronic Inc., Minneapolis, Minnesota, USA), Perceval (Sorin Group, Saluggia, Italy) and Intuity (Edwards Lifesciences, Irvine, California, USA). This article provides an overview of the available literature on sutureless aortic valves with the aim to better define current role and future perspectives of sutureless aortic bioprostheses for the treatment of aortic valve stenosis. © 2014 Il Pensiero Scientifico Editore.
2014
Aortic valve stenosis; Sutureless valves; Aortic Valve; Bioprosthesis; Heart Valve Prosthesis Implantation; Humans; Prosthesis Design; Sutures; Heart Valve Prosthesis
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/60473
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact