OBJECTIVE: Important comorbid conditions in patients referred for aortic valve replacement (AVR) require less invasive strategies. We describe our initial experience with the Perceval S (Sorin Group, Saluggia, Italy) and 3f Enable (Medtronic, Minneapolis, MN USA) sutureless aortic bioprostheses. METHODS: We compared intraoperative data, postoperative clinical outcomes, and echocardiographic results from patients receiving a Perceval S (P group; n = 97) or a 3f Enable (E group; n = 32) prosthesis in two cardiac surgery departments (Nuremberg, Germany, and Massa, Italy). RESULTS: Baseline patient characteristics were similar in both groups, except for mean ± SD body surface area (P group = 2.01 ± 2.9 m, E group = 1.83 ± 3.8 m; P < 0.001). Sixty-five patients (67%) in the P group and 19 patients (59.5%) in the E group (P = 0.22) underwent minimally invasive AVR with either ministernotomy or right anterior minithoracotomy approach. Concomitant procedures were performed in 37 patients (38%) in the P group and 9 patients (28%) in the E group (P = 0.56). In-hospital mortality was 2%. The mean ± SD prosthesis diameter was 23.5 ± 1.4 mm (P group) compared with 22.1 ± 2 mm (E group) (P < 0.001). In isolated AVR, aortic cross-clamp time was 36 ± 12.7 minutes in the P group and 66 ± 18 minutes in the E group (P < 0.001). At a mean ± SD follow-up of 8.3 ± 4.5 months, survival was 97% (one death in the P group). In five patients (P group = 1, E group = 4), a moderate paravalvular leak was present (P = 0.013). The mean ± SD transvalvular gradient was 9.1 ± 3.3 mm Hg with the Perceval S and 11.2 ± 5.2 mm Hg with the 3f Enable (P = 0.017). CONCLUSIONS: Aortic valve replacement with sutureless aortic bioprosthesis is feasible, also with a minimally invasive approach. The Perceval S showed lower operative times and moderate paravalvular leaks and lower mean transvalvular gradients than did the 3f Enable, related to the larger diameter of the Perceval S implanted. Both prostheses showed an excellent hemodynamic performance. This new technology needs long-term follow-up.

Two alternative sutureless strategies for aortic valve replacement: A two-center experience

Santarpino G.;
2013-01-01

Abstract

OBJECTIVE: Important comorbid conditions in patients referred for aortic valve replacement (AVR) require less invasive strategies. We describe our initial experience with the Perceval S (Sorin Group, Saluggia, Italy) and 3f Enable (Medtronic, Minneapolis, MN USA) sutureless aortic bioprostheses. METHODS: We compared intraoperative data, postoperative clinical outcomes, and echocardiographic results from patients receiving a Perceval S (P group; n = 97) or a 3f Enable (E group; n = 32) prosthesis in two cardiac surgery departments (Nuremberg, Germany, and Massa, Italy). RESULTS: Baseline patient characteristics were similar in both groups, except for mean ± SD body surface area (P group = 2.01 ± 2.9 m, E group = 1.83 ± 3.8 m; P < 0.001). Sixty-five patients (67%) in the P group and 19 patients (59.5%) in the E group (P = 0.22) underwent minimally invasive AVR with either ministernotomy or right anterior minithoracotomy approach. Concomitant procedures were performed in 37 patients (38%) in the P group and 9 patients (28%) in the E group (P = 0.56). In-hospital mortality was 2%. The mean ± SD prosthesis diameter was 23.5 ± 1.4 mm (P group) compared with 22.1 ± 2 mm (E group) (P < 0.001). In isolated AVR, aortic cross-clamp time was 36 ± 12.7 minutes in the P group and 66 ± 18 minutes in the E group (P < 0.001). At a mean ± SD follow-up of 8.3 ± 4.5 months, survival was 97% (one death in the P group). In five patients (P group = 1, E group = 4), a moderate paravalvular leak was present (P = 0.013). The mean ± SD transvalvular gradient was 9.1 ± 3.3 mm Hg with the Perceval S and 11.2 ± 5.2 mm Hg with the 3f Enable (P = 0.017). CONCLUSIONS: Aortic valve replacement with sutureless aortic bioprosthesis is feasible, also with a minimally invasive approach. The Perceval S showed lower operative times and moderate paravalvular leaks and lower mean transvalvular gradients than did the 3f Enable, related to the larger diameter of the Perceval S implanted. Both prostheses showed an excellent hemodynamic performance. This new technology needs long-term follow-up.
2013
Aortic valve replacement; Minimally invasive surgery; Sutureless aortic wall; Aged; Aortic Valve Stenosis; Chi-Square Distribution; Cohort Studies; Echocardiography, Doppler; Feasibility Studies; Female; Follow-Up Studies; Germany; Heart Valve Prosthesis Implantation; Humans; Italy; Male; Middle Aged; Minimally Invasive Surgical Procedures; Operative Time; Postoperative Complications; Prosthesis Design; Prosthesis Failure; Survival Rate; Sutures; Treatment Outcome; Bioprosthesis; Heart Valve Prosthesis
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/60483
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? ND
social impact