PURPOSE: To determine the appropriate choice of imaging techniques for localization of nodular lesions of parathyroid glands. MATERIALS AND METHODS: First, computed tomographic (CT), magnetic resonance (MR), ultrasonographic (US), and technetium 99m methoxyisobutyl-isonitrile (MIBI) scintigraphic images in 49 patients with primary hyperparathyroidism were retrospectively evaluated. A single-blind, prospective study that included 16 patients with primary hyperparathyroidism was then conducted. MR, US, scintigraphic, and color Doppler US images of the neck were obtained and analyzed. RESULTS: In the retrospective study, CR, MR imaging, and US had low sensitivity (13%, 17%, and 27% respectively) and specificity (39%, 65%, and 65%, respectively). Scintigraphy had 57% sensitivity and 85% specificity. In the prospective study, the use of latest-generation MR and US equipment and the participation of experienced operators led to improved sensitivity and specificity for these techniques. The combination of US and scintigraphy resulted in improved sensitivity (96%), specificity (83%), and positive and negative predictive values (88% and 94%, respectively), relative to the results obtained with either method alone. Doppler US was of little help in the setting of small glands. CONCLUSIONS: The combination of 99mTc MIBI scintigraphy and US performed by well-trained operators with up-to-date instruments appeared to be the best diagnostic tool for the preoperative diagnosis of parathyroid disease.

Parathyroid glands: Combination of 99mTc MIBI scintigraphy and US for demonstration of parathyroid glands and nodules

Amorosi A.;
2000-01-01

Abstract

PURPOSE: To determine the appropriate choice of imaging techniques for localization of nodular lesions of parathyroid glands. MATERIALS AND METHODS: First, computed tomographic (CT), magnetic resonance (MR), ultrasonographic (US), and technetium 99m methoxyisobutyl-isonitrile (MIBI) scintigraphic images in 49 patients with primary hyperparathyroidism were retrospectively evaluated. A single-blind, prospective study that included 16 patients with primary hyperparathyroidism was then conducted. MR, US, scintigraphic, and color Doppler US images of the neck were obtained and analyzed. RESULTS: In the retrospective study, CR, MR imaging, and US had low sensitivity (13%, 17%, and 27% respectively) and specificity (39%, 65%, and 65%, respectively). Scintigraphy had 57% sensitivity and 85% specificity. In the prospective study, the use of latest-generation MR and US equipment and the participation of experienced operators led to improved sensitivity and specificity for these techniques. The combination of US and scintigraphy resulted in improved sensitivity (96%), specificity (83%), and positive and negative predictive values (88% and 94%, respectively), relative to the results obtained with either method alone. Doppler US was of little help in the setting of small glands. CONCLUSIONS: The combination of 99mTc MIBI scintigraphy and US performed by well-trained operators with up-to-date instruments appeared to be the best diagnostic tool for the preoperative diagnosis of parathyroid disease.
2000
Parathyroid, CT
Parathyroid, hyperparathyroidism
Parathyroid, MR
Parathyroid, neoplasms
Parathyroid, radionuclide studies
Parathyroid, US
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/63570
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 171
  • ???jsp.display-item.citation.isi??? ND
social impact