Introduction. We investigated the accuracy of endorectal coil Magnetic Resonance Imaging (MRI) and Fast Spin Echo (FSE) technique in staging prostate cancer. Material and methods. MRI was performed in 70 patients with biopsy proved prostatic cancer. A total of 33 patients subsequently underwent radical prostatectomy. T2-weighted FSE sequences (TR 3400-4100, TE 120, Echo train length 13) were acquired in all patients. Axial, sagittal and coronal 4-5 mm images were obtained with 13-14 cm field of view and 256 × 256 matrix. Additional T1-weighted spin echo images were acquired in 9 patients. Lesion staging on MR images was performed according to the American Urological System. MR data were compared with the pathologic findings of whole-mount sections of the surgical specimens. Results. Overall accuracy for endorectal coil MR imaging was 60%; ten cases were underestimated and 3 cases were overestimated. The sensitivity and the specificity of endorectal coil MRI in diagnosing capsular penetration were 77% and 81%, respectively. Seminal vesicle invasion was detected with 87% sensitivity and 96% specificity. Conclusions. Endorectal coil MRI provides a more accurate preoperative local staging.

Endorectal MR Imaging and fast spin echo sequence for local staging of prostate cancer: Correlation with histopathology

Amorosi A.;
1997-01-01

Abstract

Introduction. We investigated the accuracy of endorectal coil Magnetic Resonance Imaging (MRI) and Fast Spin Echo (FSE) technique in staging prostate cancer. Material and methods. MRI was performed in 70 patients with biopsy proved prostatic cancer. A total of 33 patients subsequently underwent radical prostatectomy. T2-weighted FSE sequences (TR 3400-4100, TE 120, Echo train length 13) were acquired in all patients. Axial, sagittal and coronal 4-5 mm images were obtained with 13-14 cm field of view and 256 × 256 matrix. Additional T1-weighted spin echo images were acquired in 9 patients. Lesion staging on MR images was performed according to the American Urological System. MR data were compared with the pathologic findings of whole-mount sections of the surgical specimens. Results. Overall accuracy for endorectal coil MR imaging was 60%; ten cases were underestimated and 3 cases were overestimated. The sensitivity and the specificity of endorectal coil MRI in diagnosing capsular penetration were 77% and 81%, respectively. Seminal vesicle invasion was detected with 87% sensitivity and 96% specificity. Conclusions. Endorectal coil MRI provides a more accurate preoperative local staging.
1997
Prostate, cancer
Prostate, Magnetic
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/63658
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact