The objective of this work is to validate a fast and reliable 4Dbased adaptive treatment planning procedure for the Radiation Oncology clinic. A non-rigid B-Spline based registration is performed between CT scans at different respiratory phases. Radiotherapy contours drawn on a reference phase are than propagated to the target phase. We present results from two novel validation methods: a validation study using a 4D anthropomorphic computational phantom, and a patient data analysis comparing auto-rater versus inter-rater variability. For the phantom study, the overlap was greater than 90%, while the diameter variation was 5.1% at exhale and 3.4% at inhale. For the patient dataset, pairwise auto-rater Dice coefficient values exceeded inter-rater values for 9 of 15 structures. Though subject to inaccuracies caused by residual motion artifacts, and manual contouring variations, the reliability of the method suggests it could be soon introduced in the clinical practice. © 2009 IEEE.

Validation of an automatic contour propagation method for lung cancer 4D adaptive radiation therapy

Spadea M. F.
Conceptualization
;
Baroni G.;
2009-01-01

Abstract

The objective of this work is to validate a fast and reliable 4Dbased adaptive treatment planning procedure for the Radiation Oncology clinic. A non-rigid B-Spline based registration is performed between CT scans at different respiratory phases. Radiotherapy contours drawn on a reference phase are than propagated to the target phase. We present results from two novel validation methods: a validation study using a 4D anthropomorphic computational phantom, and a patient data analysis comparing auto-rater versus inter-rater variability. For the phantom study, the overlap was greater than 90%, while the diameter variation was 5.1% at exhale and 3.4% at inhale. For the patient dataset, pairwise auto-rater Dice coefficient values exceeded inter-rater values for 9 of 15 structures. Though subject to inaccuracies caused by residual motion artifacts, and manual contouring variations, the reliability of the method suggests it could be soon introduced in the clinical practice. © 2009 IEEE.
2009
4D treatment planning
Adaptive radiation therapy
Contour propagation
Deformable registration
Re-planning
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/64275
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? ND
social impact