Aim: To investigate the variation in biological effective dose (BED) produced by the uncertainty in absorbed dose and radiobiological parameters in Zevalin radioimmunotherapy. Methods: Eight patients scheduled for treatment with standard administration of 90Y-ibritumomab tiuxetan (Zevalin) were studied. Patient-specific pretherapy dosimetry was performed by injection of 111In-ibritumomab tiuxetan. Absorbed doses and BEDs were calculated for critical organs (COs) and tumours, assuming a 30% dose uncertainty and varying the radiobiological parameters in a reasonable range. In an activity-escalation study, BEDs for the COs were compared with the BED limits of external beam radiotherapy (EBRT) and BEDs for the tumour with the EBRT dose prescriptions. Results: At standard activities, the absorbed doses per unit activity for the COs were in agreement with those in the literature. Absorbed doses to lesions were rather variable, ranging from 1.47 to 16.7 Gy/GBq. Median tumour absorbed dose to lesions in the range 80-110 g was 9.6 Gy/GBq (range 9.2-16.7 Gy/GBq), yielding a mean BED of about 12 Gy for administration of 15 MBq/kg. For the administration of the myeloablative activity of 45 MBq/kg, risk of liver toxicity in one patient would have been foreseen by the model. Considering also the dose uncertainty, the potential risk of liver toxicity in one more patient, lung toxicity in one patient, and kidney toxicity in one patient would have been suggested. The absorbed dose uncertainty was found to be the main source of uncertainty in the BED. As for radiobiological parameters, at myeloablative activities, the increase in the repair half-time for sublethally damaged tissue (Tμ) from 0.5 h to 5 h induced more consistent increases in mean BED/BEDlimit than α/β variation from 2 Gy to 5 Gy: at 53 MBq/kg, 38% for the liver, and 34% for the lungs and kidneys (about threefold higher than that obtained for the increase α/β). Conclusion: At standard activities, absorbed doses to lesions appear to be effective, even though lower than prescribed by EBRT. At myeloablative dosages, the uncertainty associated with the absorbed doses and radiobiological parameters considerably affect BED evaluation and may account for possible "second-organ" toxicities. © 2009 Springer-Verlag.

A theoretical dose-escalation study based on biological effective dose in radioimmunotherapy with 90Y-ibritumomab tiuxetan (Zevalin)

Cicone F.;
2010-01-01

Abstract

Aim: To investigate the variation in biological effective dose (BED) produced by the uncertainty in absorbed dose and radiobiological parameters in Zevalin radioimmunotherapy. Methods: Eight patients scheduled for treatment with standard administration of 90Y-ibritumomab tiuxetan (Zevalin) were studied. Patient-specific pretherapy dosimetry was performed by injection of 111In-ibritumomab tiuxetan. Absorbed doses and BEDs were calculated for critical organs (COs) and tumours, assuming a 30% dose uncertainty and varying the radiobiological parameters in a reasonable range. In an activity-escalation study, BEDs for the COs were compared with the BED limits of external beam radiotherapy (EBRT) and BEDs for the tumour with the EBRT dose prescriptions. Results: At standard activities, the absorbed doses per unit activity for the COs were in agreement with those in the literature. Absorbed doses to lesions were rather variable, ranging from 1.47 to 16.7 Gy/GBq. Median tumour absorbed dose to lesions in the range 80-110 g was 9.6 Gy/GBq (range 9.2-16.7 Gy/GBq), yielding a mean BED of about 12 Gy for administration of 15 MBq/kg. For the administration of the myeloablative activity of 45 MBq/kg, risk of liver toxicity in one patient would have been foreseen by the model. Considering also the dose uncertainty, the potential risk of liver toxicity in one more patient, lung toxicity in one patient, and kidney toxicity in one patient would have been suggested. The absorbed dose uncertainty was found to be the main source of uncertainty in the BED. As for radiobiological parameters, at myeloablative activities, the increase in the repair half-time for sublethally damaged tissue (Tμ) from 0.5 h to 5 h induced more consistent increases in mean BED/BEDlimit than α/β variation from 2 Gy to 5 Gy: at 53 MBq/kg, 38% for the liver, and 34% for the lungs and kidneys (about threefold higher than that obtained for the increase α/β). Conclusion: At standard activities, absorbed doses to lesions appear to be effective, even though lower than prescribed by EBRT. At myeloablative dosages, the uncertainty associated with the absorbed doses and radiobiological parameters considerably affect BED evaluation and may account for possible "second-organ" toxicities. © 2009 Springer-Verlag.
2010
BED
Dosimetry
Lymphoma
Radioimmunotherapy
Zevalin
Aged
Antibodies, Monoclonal
Bone Marrow
Dose-Response Relationship, Radiation
Female
Humans
Male
Middle Aged
Neoplasms
Radiometry
Radiotherapy Dosage
Treatment Outcome
Uncertainty
Radioimmunotherapy
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/64748
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 15
social impact