Background: Adolescent idiopathic scoliosis screening still needs a considerable implementation, particularly throughout a school-based assessment protocol. Objective: This study aims to evaluate the effectiveness of clinical examinations currently in use for the diagnosis of adolescent idiopathic scoliosis, through a survey carried out in secondary schools to standardize a screening protocol that could be generalized. Methods: In their classrooms, the adolescents underwent an idiopathic scoliosis screening through three examinations: Adam's test, axial trunk rotation (ATR) and plumb line. In case of single positivity to one of the three examinations, a column X-ray examination was recommended. Results: The sensitivity and diagnostic specificity of Adam's test or ATR were 56.3% and 92.7%, respectively. The positivity to at least one between ATR or plumb line showed that sensitivity was higher than specificity: 91.3% versus 80.8%; the positivity to at least one between Adams's test or plumb line showed a sensitivity of 95.2% and a specificity of 81.5%. Finally, the positivity to all three examinations showed an increase in specificity (99.7%). Conclusions: Taken together, our findings show that this school-based screening protocol had a very high specificity in early diagnosis of adolescent idiopathic scoliosis.

Adolescent idiopathic scoliosis screening: Could a school-based assessment protocol be useful for an early diagnosis?

de Sire, Alessandro;
2020-01-01

Abstract

Background: Adolescent idiopathic scoliosis screening still needs a considerable implementation, particularly throughout a school-based assessment protocol. Objective: This study aims to evaluate the effectiveness of clinical examinations currently in use for the diagnosis of adolescent idiopathic scoliosis, through a survey carried out in secondary schools to standardize a screening protocol that could be generalized. Methods: In their classrooms, the adolescents underwent an idiopathic scoliosis screening through three examinations: Adam's test, axial trunk rotation (ATR) and plumb line. In case of single positivity to one of the three examinations, a column X-ray examination was recommended. Results: The sensitivity and diagnostic specificity of Adam's test or ATR were 56.3% and 92.7%, respectively. The positivity to at least one between ATR or plumb line showed that sensitivity was higher than specificity: 91.3% versus 80.8%; the positivity to at least one between Adams's test or plumb line showed a sensitivity of 95.2% and a specificity of 81.5%. Finally, the positivity to all three examinations showed an increase in specificity (99.7%). Conclusions: Taken together, our findings show that this school-based screening protocol had a very high specificity in early diagnosis of adolescent idiopathic scoliosis.
2020
Scoliosis
adam’s test
axial trunk rotation
plumb line
spine deformities
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/66944
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 14
social impact