Abstract Previous studies have shown that radiofrequency thermal ablation (RFA) of uterine fibroids through a percutaneous ultrasound (US)-guided procedure is an effective and safe minimally invasive treatment, with encouraging short-term results. The aim of this study was to assess the results in terms of volume reduction and clinical symptoms improvement in the midterm follow-up of fibroids with a diameter of up to 8 cm. Eleven premenopausal females affected by symptomatic fibroids underwent percutaneous US-guided RFA. Symptom severity and reduction in volume were evaluated at 1, 3, 6, 9, and 12 months. The mean symptom score (SSS) before the procedure was 50.30 (range 31.8–67.30), and the average quality of life (QOL) score value was 62 (range 37.20–86.00). The mean basal diameter was 5.5 cm (range 4.4–8) and the mean volume was 101.5 cm3 (range 44.58–278 cm3). The mean follow-up was 9 months (range 3–12 months). The mean SSS value at the end of the follow-up was 13.38 (range 0–67.1) and the QOL 90.4 (range 43.8–100). At follow-up the mean diameter was 3.0 cm (range 1.20– 4.5 cm), and the mean volume was 18 cm3 (range 0.90– 47.6 cm3). In 10 of 11 patients we obtained total or partial regression of symptoms. In one case the clinical manifestations persisted and it was thus considered unsuccessful. In conclusion, US-guided percutaneous RFA is a safe and effective treatment even for fibroids up to 8 cm.

Ultrasound-Guided Radiofrequency Thermal Ablation of Uterine Fibroids: Medium-Term Follow-Up

LAGANÀ D;
2010-01-01

Abstract

Abstract Previous studies have shown that radiofrequency thermal ablation (RFA) of uterine fibroids through a percutaneous ultrasound (US)-guided procedure is an effective and safe minimally invasive treatment, with encouraging short-term results. The aim of this study was to assess the results in terms of volume reduction and clinical symptoms improvement in the midterm follow-up of fibroids with a diameter of up to 8 cm. Eleven premenopausal females affected by symptomatic fibroids underwent percutaneous US-guided RFA. Symptom severity and reduction in volume were evaluated at 1, 3, 6, 9, and 12 months. The mean symptom score (SSS) before the procedure was 50.30 (range 31.8–67.30), and the average quality of life (QOL) score value was 62 (range 37.20–86.00). The mean basal diameter was 5.5 cm (range 4.4–8) and the mean volume was 101.5 cm3 (range 44.58–278 cm3). The mean follow-up was 9 months (range 3–12 months). The mean SSS value at the end of the follow-up was 13.38 (range 0–67.1) and the QOL 90.4 (range 43.8–100). At follow-up the mean diameter was 3.0 cm (range 1.20– 4.5 cm), and the mean volume was 18 cm3 (range 0.90– 47.6 cm3). In 10 of 11 patients we obtained total or partial regression of symptoms. In one case the clinical manifestations persisted and it was thus considered unsuccessful. In conclusion, US-guided percutaneous RFA is a safe and effective treatment even for fibroids up to 8 cm.
2010
Uterine fibroids
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/6826
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 30
  • ???jsp.display-item.citation.isi??? 31
social impact