Ten years ago, for the first time in humans, thanks to the DLMS (direct metal laser sintering) technique, we designed, built and inserted an immediate post-extraction custom-made root-analogue implant in Ti-6Al-4v with platform switching. The implant was inserted into the post-extraction socket, respecting the biological width. After 10 years, we wanted to evaluate the dimensional stability of the implant and the eventual crestal bone resorption. The evaluation was performed clinically with periodontal parameters and radiographically by means of an intraoral X-ray with the parallel technique measuring the distance between the base of the bone crest and the implant shoulder. It appears that the implant has maintained dimensional stability of the peri-implant soft tissues, and the crestal resorption is 0 mm. This could represent a step forward to make this experimental method a valid alternative to the current immediate post-extraction implant procedures in use.

10-Year Evaluation of the First Root Analogue Implant on Humans, Made Using a CT Scan, CAD/CAM and DMLS

Figliuzzi, Michele Mario
;
2022-01-01

Abstract

Ten years ago, for the first time in humans, thanks to the DLMS (direct metal laser sintering) technique, we designed, built and inserted an immediate post-extraction custom-made root-analogue implant in Ti-6Al-4v with platform switching. The implant was inserted into the post-extraction socket, respecting the biological width. After 10 years, we wanted to evaluate the dimensional stability of the implant and the eventual crestal bone resorption. The evaluation was performed clinically with periodontal parameters and radiographically by means of an intraoral X-ray with the parallel technique measuring the distance between the base of the bone crest and the implant shoulder. It appears that the implant has maintained dimensional stability of the peri-implant soft tissues, and the crestal resorption is 0 mm. This could represent a step forward to make this experimental method a valid alternative to the current immediate post-extraction implant procedures in use.
2022
CAD/CAM
DLMS
implants
root-analogue
titanium
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/77372
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact