To test the hypothesis of association between heart failure and altered haemostatic balance in patients with a mechanical valve prosthesis, comparisons were made between 20 patients with mitral valve replacement and stable chronic heart failure (group A), 20 with the same prosthesis but satisfactory haemodynamics (group B) and 20 age-matched controls (group C). The left ventricular ejection fraction was significantly highest (p < 0.001) in group A. The pulmonary artery systolic pressure was also highest in group A (p < 0.001), without significant difference between groups B and C. Two group A patients had a transient ischaemic attack. The D-dimer plasma concentrations and the antigenic and biologic von Willebrand factor activities were significantly greatest in group A. Significant correlation was found between the plasma concentrations of these activities and pulmonary artery systolic pressure and between D-dimer and ejection fraction. Platelet-activating factor was detected only in six group A patients. The observed relationship between haemostatic factors and heart failure in patients with mechanical heart-valve prosthesis advocates careful evaluation of von Willebrand factor and D-dimer in order to prevent embolic events in such cases.

Elevated circulating levels of vonWillebrand factor and D-dimer in patients with heart failure and mechanical prosthesis

MASTROROBERTO P;
1996-01-01

Abstract

To test the hypothesis of association between heart failure and altered haemostatic balance in patients with a mechanical valve prosthesis, comparisons were made between 20 patients with mitral valve replacement and stable chronic heart failure (group A), 20 with the same prosthesis but satisfactory haemodynamics (group B) and 20 age-matched controls (group C). The left ventricular ejection fraction was significantly highest (p < 0.001) in group A. The pulmonary artery systolic pressure was also highest in group A (p < 0.001), without significant difference between groups B and C. Two group A patients had a transient ischaemic attack. The D-dimer plasma concentrations and the antigenic and biologic von Willebrand factor activities were significantly greatest in group A. Significant correlation was found between the plasma concentrations of these activities and pulmonary artery systolic pressure and between D-dimer and ejection fraction. Platelet-activating factor was detected only in six group A patients. The observed relationship between haemostatic factors and heart failure in patients with mechanical heart-valve prosthesis advocates careful evaluation of von Willebrand factor and D-dimer in order to prevent embolic events in such cases.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/8849
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact