The use of programmed electrical stimulation in the long term treatment of re-entry tachycardia offers encouraging perspectives. Among the others proposed, the "scanning" system seems to be the most effective. However, an implantable stimulator with these features is not yet available and, thus, a temporary external lead is required. These difficulties have been overcome by utilizing radiofrequency to synchronize and stimulate. An implantable device was therefore designed which is triggered by the patient and automatically searches the interruption zone of the tachycardia by exploring the R-R cycle. The external transmitter, which can produce one or two synchronized impulses, is programmed to scan the R-R cycle with progressive steps of 5 or 10 ms; when tachycardia is interrupted, further stimulation is inhibited. The implanted module connected to an endocavitary lead does not have any power supply and, therefore, is very small. The efficacy of this method has been demonstrated in 4 patients with supraventricular tachycardia (3 with WPW syndrome) resistant to conventional pharmacologic therapy.

Automatic "scanning" by radiofrequency in the long-term electrical treatment of arrhythmias.

Perticone F;
1979-01-01

Abstract

The use of programmed electrical stimulation in the long term treatment of re-entry tachycardia offers encouraging perspectives. Among the others proposed, the "scanning" system seems to be the most effective. However, an implantable stimulator with these features is not yet available and, thus, a temporary external lead is required. These difficulties have been overcome by utilizing radiofrequency to synchronize and stimulate. An implantable device was therefore designed which is triggered by the patient and automatically searches the interruption zone of the tachycardia by exploring the R-R cycle. The external transmitter, which can produce one or two synchronized impulses, is programmed to scan the R-R cycle with progressive steps of 5 or 10 ms; when tachycardia is interrupted, further stimulation is inhibited. The implanted module connected to an endocavitary lead does not have any power supply and, therefore, is very small. The efficacy of this method has been demonstrated in 4 patients with supraventricular tachycardia (3 with WPW syndrome) resistant to conventional pharmacologic therapy.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/8917
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact