PURPOSE: We analyzed the efficacy of a point-of-care ultrasonographic protocol, based on a focused multiorgan examination, for the diagnostic process of symptomatic, non-traumatic hypotensive patients in the emergency department. METHODS: We prospectively enrolled 108 adult patients complaining of non-traumatic symptomatic hypotension of uncertain etiology. Patients received immediate point-of-care ultrasonography to determine cardiac function and right/left ventricle diameter rate, inferior vena cava diameter and collapsibility, pulmonary congestion, consolidations and sliding, abdominal free fluid and aortic aneurysm, and leg vein thrombosis. The organ-oriented diagnoses were combined to formulate an ultrasonographic hypothesis of the cause of hemodynamic instability. The ultrasonographic diagnosis was then compared with a final clinical diagnosis obtained by agreement of three independent expert physicians who performed a retrospective hospital chart review of each case. RESULTS: Considering the whole population, concordance between the point-of-care ultrasonography diagnosis and the final clinical diagnosis was interpreted as good, with Cohen's k = 0.710 (95 % CI, 0.614-0.806), p < 0.0001 and raw agreement (Ra) = 0.768. By eliminating the 13 cases where the final clinical diagnosis was not agreed upon (indefinite), the concordance increased to almost perfect, with k = 0.971 (95 % CI, 0.932-1.000), p < 0.0001 and Ra = 0.978. CONCLUSIONS: Emergency diagnostic judgments guided by point-of-care multiorgan ultrasonography in patients presenting with undifferentiated hypotension significantly agreed with a final clinical diagnosis obtained by retrospective chart review. The integration of an ultrasonographic multiorgan protocol in the diagnostic process of undifferentiated hypotension has great potential in guiding the first-line therapeutic approach.

Point-of-care multiorgan ultrasonography for the evaluation of undifferentiated hypotension in the emergency department

Volpicelli G;
2013-01-01

Abstract

PURPOSE: We analyzed the efficacy of a point-of-care ultrasonographic protocol, based on a focused multiorgan examination, for the diagnostic process of symptomatic, non-traumatic hypotensive patients in the emergency department. METHODS: We prospectively enrolled 108 adult patients complaining of non-traumatic symptomatic hypotension of uncertain etiology. Patients received immediate point-of-care ultrasonography to determine cardiac function and right/left ventricle diameter rate, inferior vena cava diameter and collapsibility, pulmonary congestion, consolidations and sliding, abdominal free fluid and aortic aneurysm, and leg vein thrombosis. The organ-oriented diagnoses were combined to formulate an ultrasonographic hypothesis of the cause of hemodynamic instability. The ultrasonographic diagnosis was then compared with a final clinical diagnosis obtained by agreement of three independent expert physicians who performed a retrospective hospital chart review of each case. RESULTS: Considering the whole population, concordance between the point-of-care ultrasonography diagnosis and the final clinical diagnosis was interpreted as good, with Cohen's k = 0.710 (95 % CI, 0.614-0.806), p < 0.0001 and raw agreement (Ra) = 0.768. By eliminating the 13 cases where the final clinical diagnosis was not agreed upon (indefinite), the concordance increased to almost perfect, with k = 0.971 (95 % CI, 0.932-1.000), p < 0.0001 and Ra = 0.978. CONCLUSIONS: Emergency diagnostic judgments guided by point-of-care multiorgan ultrasonography in patients presenting with undifferentiated hypotension significantly agreed with a final clinical diagnosis obtained by retrospective chart review. The integration of an ultrasonographic multiorgan protocol in the diagnostic process of undifferentiated hypotension has great potential in guiding the first-line therapeutic approach.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/90376
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 194
  • ???jsp.display-item.citation.isi??? 161
social impact