Objectives: To assess the potential of bedside lung ultrasound to diagnose the radiologic alveolarinterstitial syndrome (AIS) in patients admitted to an emergency medicine unit and to estimate the occurrence of ultrasound pattern of diffuse and multiple comet tail artifacts in diseases involving lung interstitium. Methods: The ultrasonic feature of multiple and diffuse comet tail artifacts B line was investigated in each of 300 consecutive patients within 48 hours after admission to our emergency medicine unit. Sonographic examination was performed at bedside in a supine position. Eight anterolateral ultrasound chest intercostal scans were obtained for each patient. Results: The artifact showed a sensitivity of 85.7% and a specificity of 97.7% in recognition of radiologic AIS. Corresponding figures in the identification of a disease involving lung interstitium were 85.3% and 96.8%. Conclusion: Comet tail artifact B line is a lung ultrasound sign reasonably accurate for diagnosing AIS at bedside.

Bedside lung ultrasound in the assessment of alveolar-interstitial syndrome

Volpicelli G;
2006-01-01

Abstract

Objectives: To assess the potential of bedside lung ultrasound to diagnose the radiologic alveolarinterstitial syndrome (AIS) in patients admitted to an emergency medicine unit and to estimate the occurrence of ultrasound pattern of diffuse and multiple comet tail artifacts in diseases involving lung interstitium. Methods: The ultrasonic feature of multiple and diffuse comet tail artifacts B line was investigated in each of 300 consecutive patients within 48 hours after admission to our emergency medicine unit. Sonographic examination was performed at bedside in a supine position. Eight anterolateral ultrasound chest intercostal scans were obtained for each patient. Results: The artifact showed a sensitivity of 85.7% and a specificity of 97.7% in recognition of radiologic AIS. Corresponding figures in the identification of a disease involving lung interstitium were 85.3% and 96.8%. Conclusion: Comet tail artifact B line is a lung ultrasound sign reasonably accurate for diagnosing AIS at bedside.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/90383
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 442
  • ???jsp.display-item.citation.isi??? 390
social impact