PURPOSE: Flow-mediated dilation (FMD) is a complex mechanism involving several mediators, and different hemodynamic forces. Temporally distinct FMD patterns can be elicited by ischemic stimulus. Some subjects dilate early after cuff release, while others dilate later or do not dilate at all. Aim of the present research was to verify if hemorheological and hemodynamic factors might influence different FMD pattern. METHODS: 148 free-living subjects were studied. FMD was measured at 50 s, 2 min and 3 min. Blood viscosity was measured and shear stress calculated. Shear stress stimulus was quantified as the area under the curve after ischemia (SSAUC) over the first 40-s post-occlusion. RESULTS: Based on the timing or absence of arterial dilation, 82 subjects were classified as Early dilators, 37 as Late dilators and 29 as No dilators. Peak FMD was 7.9 ± 4.3 % in Early dilators, and 9.1 ± 5.7 in Late dilators (p = NS). SSAUC was not significantly different among three groups, while blood viscosity was significantly higher in Late FMD subjects. Regression analyses showed the independent predictive role of age and blood viscosity on FMD patterns, and the lack of any association between FMD pattern and the magnitude of SS. CONCLUSIONS: The present study demonstrates that age and blood viscosity but not the magnitude of SS explain the different timing of the dilatory response to ischemia.

Blood viscosity but not shear stress associated with delayed flow-mediated dilation

Irace C;Gnasso A
2015-01-01

Abstract

PURPOSE: Flow-mediated dilation (FMD) is a complex mechanism involving several mediators, and different hemodynamic forces. Temporally distinct FMD patterns can be elicited by ischemic stimulus. Some subjects dilate early after cuff release, while others dilate later or do not dilate at all. Aim of the present research was to verify if hemorheological and hemodynamic factors might influence different FMD pattern. METHODS: 148 free-living subjects were studied. FMD was measured at 50 s, 2 min and 3 min. Blood viscosity was measured and shear stress calculated. Shear stress stimulus was quantified as the area under the curve after ischemia (SSAUC) over the first 40-s post-occlusion. RESULTS: Based on the timing or absence of arterial dilation, 82 subjects were classified as Early dilators, 37 as Late dilators and 29 as No dilators. Peak FMD was 7.9 ± 4.3 % in Early dilators, and 9.1 ± 5.7 in Late dilators (p = NS). SSAUC was not significantly different among three groups, while blood viscosity was significantly higher in Late FMD subjects. Regression analyses showed the independent predictive role of age and blood viscosity on FMD patterns, and the lack of any association between FMD pattern and the magnitude of SS. CONCLUSIONS: The present study demonstrates that age and blood viscosity but not the magnitude of SS explain the different timing of the dilatory response to ischemia.
2015
blood viscosity; shear stress; endothelial function
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/9416
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 7
social impact