BACKGROUND: During a fluid challenge, the changes in cardiac performance and peripheral circulatory tone are closely related to the position of the ventricle on the Frank-Starling curve. Some patients have a good haemodynamic response to a fluid challenge, others hardly any response. The early haemodynamic effects of a fluid challenge could predict the final response before the entire fluid volume has been administered. OBJECTIVE: To assess whether a multivariate logistic regression model, including pulse pressure variation (PPV), cardiac cycle efficiency (CCE), arterial elastance and the difference between the dicrotic pressure and both systolic and mean arterial pressure (SAP - Pdic and MAP - Pdic) can predict cardiac responsiveness early during a fluid challenge in comparison with the standard procedure described elsewhere. DESIGN: Observational study. SETTING: Elective surgical patients undergoing laparotomy, enrolled in two Italian University Hospitals. PATIENTS: Fifty adult surgical patients, ventilated with a lung protective strategy, were enrolled and data from 46 were analysed. INTERVENTIONS: A fluid challenge consisting of 500 ml of crystalloid infused over 10 min. MAIN OUTCOME MEASURES AND ANALYSIS: The changes in CCE, arterial elastance, SAP - Pdic and MAP - Pdic were compared using analysis of variance. A multivariate logistic regression analysis utilising baseline values and the first minute measuring a variation statistically significant for the considered variables. RESULTS: At baseline, PPV correctly identified 70% of patients (89% of non-responders; 42% of responders). The model, including baseline PPV, ΔCCE and ΔSAP - Pdic, correctly identified the efficiency of fluid challenge in 87% of patients (84.2% of responders; 92.5 of non-responders) after 5 min from fluid challenge infusion. CONCLUSION: In this pilot study conducted in a population of surgical patients mechanically ventilated with a VT less than 8 ml kg, a dynamic model of fluid challenge assessment, including PPV, ΔCCE and ΔSAP - Pdic, enhances the prediction of fluid challenge response after 5 min of a 10-min administration. TRIAL REGISTRATION: ACTRN12616001479493.

Cardiac cycle efficiency and dicrotic pressure variations: new parameters for fluid therapy: An observational study

Navalesi P;
2017-01-01

Abstract

BACKGROUND: During a fluid challenge, the changes in cardiac performance and peripheral circulatory tone are closely related to the position of the ventricle on the Frank-Starling curve. Some patients have a good haemodynamic response to a fluid challenge, others hardly any response. The early haemodynamic effects of a fluid challenge could predict the final response before the entire fluid volume has been administered. OBJECTIVE: To assess whether a multivariate logistic regression model, including pulse pressure variation (PPV), cardiac cycle efficiency (CCE), arterial elastance and the difference between the dicrotic pressure and both systolic and mean arterial pressure (SAP - Pdic and MAP - Pdic) can predict cardiac responsiveness early during a fluid challenge in comparison with the standard procedure described elsewhere. DESIGN: Observational study. SETTING: Elective surgical patients undergoing laparotomy, enrolled in two Italian University Hospitals. PATIENTS: Fifty adult surgical patients, ventilated with a lung protective strategy, were enrolled and data from 46 were analysed. INTERVENTIONS: A fluid challenge consisting of 500 ml of crystalloid infused over 10 min. MAIN OUTCOME MEASURES AND ANALYSIS: The changes in CCE, arterial elastance, SAP - Pdic and MAP - Pdic were compared using analysis of variance. A multivariate logistic regression analysis utilising baseline values and the first minute measuring a variation statistically significant for the considered variables. RESULTS: At baseline, PPV correctly identified 70% of patients (89% of non-responders; 42% of responders). The model, including baseline PPV, ΔCCE and ΔSAP - Pdic, correctly identified the efficiency of fluid challenge in 87% of patients (84.2% of responders; 92.5 of non-responders) after 5 min from fluid challenge infusion. CONCLUSION: In this pilot study conducted in a population of surgical patients mechanically ventilated with a VT less than 8 ml kg, a dynamic model of fluid challenge assessment, including PPV, ΔCCE and ΔSAP - Pdic, enhances the prediction of fluid challenge response after 5 min of a 10-min administration. TRIAL REGISTRATION: ACTRN12616001479493.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/9851
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact