Background: Safety of central venous catheter (CVC) placement relies on some general aspects, including selection of the right vessel, correct lumen targeting while inserting the needle, check the position of catheter tip, and post-procedure check for complications. All these four points can be guided by bedside ultrasound, but the best technique to ensure the position of the CVC tip is still uncertain. Methods: We investigated feasibility of a novel ultrasound technique consisting of focused view of guidewire tip in the cavoatrial junction (CAJ) to calculate the CVC depth in adult patients needing CVC placement in emergency. Direct visualization of the guidewire in the CAJ was used to calculate how deep the CVC needed to be inserted. In those patients without a valid CAJ window, a bubble test in the right atrium was performed to position the CVC tip. In all cases chest radiography confirmed the CVC position. Results: The procedure was performed in 37 patients and CVC was correctly placed in all cases. Within the group, in 25 patients the CVC depth (21.5 ± 6.0 cm) was successfully measured. In other 11 patients the correct CVC tip position was confirmed by the bubble test. In only one case it was not possible to use ultrasound for incomplete CAJ and right atrium views. Conclusions: This study confirms the feasibility of a new ultrasound method to ensure the correct CVC tip position. This protocol could potentially become a standard method reducing costs, post-procedural irradiation, and time of CVC placement in emergency.

Feasibility of a new ultrasound guided procedure to ensure the correct position of the central venous catheter tip

Volpicelli, Giovanni;
2024-01-01

Abstract

Background: Safety of central venous catheter (CVC) placement relies on some general aspects, including selection of the right vessel, correct lumen targeting while inserting the needle, check the position of catheter tip, and post-procedure check for complications. All these four points can be guided by bedside ultrasound, but the best technique to ensure the position of the CVC tip is still uncertain. Methods: We investigated feasibility of a novel ultrasound technique consisting of focused view of guidewire tip in the cavoatrial junction (CAJ) to calculate the CVC depth in adult patients needing CVC placement in emergency. Direct visualization of the guidewire in the CAJ was used to calculate how deep the CVC needed to be inserted. In those patients without a valid CAJ window, a bubble test in the right atrium was performed to position the CVC tip. In all cases chest radiography confirmed the CVC position. Results: The procedure was performed in 37 patients and CVC was correctly placed in all cases. Within the group, in 25 patients the CVC depth (21.5 ± 6.0 cm) was successfully measured. In other 11 patients the correct CVC tip position was confirmed by the bubble test. In only one case it was not possible to use ultrasound for incomplete CAJ and right atrium views. Conclusions: This study confirms the feasibility of a new ultrasound method to ensure the correct CVC tip position. This protocol could potentially become a standard method reducing costs, post-procedural irradiation, and time of CVC placement in emergency.
2024
Central venous access
Central venous catheter
Emergency ultrasound
Ultrasound guidance
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/98837
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact