: Low-profile stents may provide significant advantages in Y-stent-assisted coiling due to their miniaturized design and capability to be delivered through a 0.0165-inch microcatheter. We aim to investigate the safety and efficacy of using these newer versions of stents in Y-stent-assisted coiling for the treatment of wide-necked bifurcation aneurysms. We conducted a systematic review of the PubMed, Embase, Cochrane Library, and Web of Science databases up to September 2023, following the PRISMA guidelines. Eligible studies included  ≥ 5 patients with intracranial wide-necked bifurcation aneurysms treated with Y-stent-assisted coiling using low-profile stents, providing angiographic and clinical outcomes. Two authors independently handled the search and selection. Primary outcomes were immediate and follow-up aneurysm occlusion, procedure-related complications, aneurysm recanalization, and retreatment. Secondary outcomes included technical success, procedure-related morbidity, procedure-related mortality, procedure-related stroke, and in-stent stenosis at follow-up. We analyzed the data using random-effects meta-analysis. In total, 19 studies including 507 patients with 509 aneurysms were included. 95% of the treated aneurysms were managed using the crossing Y-configuration. Technical success rate was 99%. Immediate adequate aneurysm occlusion was 90%. Follow-up angiographies were available for 443 aneurysms. The mean angiographic follow-up duration was 15.6 ± 1.9 months. The rates for follow-up adequate aneurysm occlusion and complete occlusion were 98% and 89%, respectively. After a mean clinical follow-up of 15 ± 2.4 months, a good clinical outcome was observed in 98% of patients. Overall, procedure-related morbidity and mortality rates were 1.3%, and 0.4%, respectively. Low-profile stents in Y-stent-assisted coiling outperform previous stent versions in terms of safety, efficacy, and technical success rates.

Efficacy and safety of low profile stents in Y-stent assisted coil embolization of wide-necked bifurcation aneurysms: a systematic review and meta-analysis

Ciccio, G.
Methodology
2024-01-01

Abstract

: Low-profile stents may provide significant advantages in Y-stent-assisted coiling due to their miniaturized design and capability to be delivered through a 0.0165-inch microcatheter. We aim to investigate the safety and efficacy of using these newer versions of stents in Y-stent-assisted coiling for the treatment of wide-necked bifurcation aneurysms. We conducted a systematic review of the PubMed, Embase, Cochrane Library, and Web of Science databases up to September 2023, following the PRISMA guidelines. Eligible studies included  ≥ 5 patients with intracranial wide-necked bifurcation aneurysms treated with Y-stent-assisted coiling using low-profile stents, providing angiographic and clinical outcomes. Two authors independently handled the search and selection. Primary outcomes were immediate and follow-up aneurysm occlusion, procedure-related complications, aneurysm recanalization, and retreatment. Secondary outcomes included technical success, procedure-related morbidity, procedure-related mortality, procedure-related stroke, and in-stent stenosis at follow-up. We analyzed the data using random-effects meta-analysis. In total, 19 studies including 507 patients with 509 aneurysms were included. 95% of the treated aneurysms were managed using the crossing Y-configuration. Technical success rate was 99%. Immediate adequate aneurysm occlusion was 90%. Follow-up angiographies were available for 443 aneurysms. The mean angiographic follow-up duration was 15.6 ± 1.9 months. The rates for follow-up adequate aneurysm occlusion and complete occlusion were 98% and 89%, respectively. After a mean clinical follow-up of 15 ± 2.4 months, a good clinical outcome was observed in 98% of patients. Overall, procedure-related morbidity and mortality rates were 1.3%, and 0.4%, respectively. Low-profile stents in Y-stent-assisted coiling outperform previous stent versions in terms of safety, efficacy, and technical success rates.
2024
Aneurysm
Bifurcation
Coiling
Low-profile stents
Wide-necked
Y-stent-assisted
Y-stenting
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/99457
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact