In the current clinical practice, the diagnosis of Rheumatoid Arthritis (RA) draws on the qualitative evaluation of pain sensitivity thresholds which is affected by several source of uncertainties, due to an operator-dependent diagnostic protocol. Taking our cue from the diagnostic shortcomings, we have explored the possibility of automating the measurement of mechanical nociceptive thresholds through the adoption of soft pneumatic actuators controlled by an embedded control unit. In this work, we want to show that a purpose-made biomechatronic device actuated by soft and pneumatic actuators is potentially a boon both for rheumatologists and biomedical researchers involved in nociception and physicophysical studies. In the full breadth and scope of the objective diagnosis of RA, the first prototype of a novel biomechatronic device for quantitative and automatic measurement of mechanical nociceptive thresholds has been designed and tested through nociception experiments on 10 subjects. The experimental results show that the designed device can reliably generate the controllable and repeatable nociceptive stimuli needed for the objective diagnosis of RA.

A biomechatronic device actuated by pneumatic artificial muscles for the automatic evaluation of nociceptive thresholds in rheumatic patients

Randazzini L.;Capace A.;Cosentino C.
;
Grembiale R. D.;Merola A.
2020-01-01

Abstract

In the current clinical practice, the diagnosis of Rheumatoid Arthritis (RA) draws on the qualitative evaluation of pain sensitivity thresholds which is affected by several source of uncertainties, due to an operator-dependent diagnostic protocol. Taking our cue from the diagnostic shortcomings, we have explored the possibility of automating the measurement of mechanical nociceptive thresholds through the adoption of soft pneumatic actuators controlled by an embedded control unit. In this work, we want to show that a purpose-made biomechatronic device actuated by soft and pneumatic actuators is potentially a boon both for rheumatologists and biomedical researchers involved in nociception and physicophysical studies. In the full breadth and scope of the objective diagnosis of RA, the first prototype of a novel biomechatronic device for quantitative and automatic measurement of mechanical nociceptive thresholds has been designed and tested through nociception experiments on 10 subjects. The experimental results show that the designed device can reliably generate the controllable and repeatable nociceptive stimuli needed for the objective diagnosis of RA.
2020
Automated diagnosis
Haptic devices
Pneumatic artificial muscle
Rheumatic diseases
Soft robotics
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12317/63916
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact